J Knee Surg 2018; 31(04): 348-351
DOI: 10.1055/s-0037-1603796
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Use of Shorter Intramedullary Guide for Ipsilateral Total Knee Arthroplasty following Prior Total Hip Arthroplasty

Bradley T. Webb
1   University of Louisville Adult Reconstruction Program, Louisville, Kentucky
,
Slif D. Ulrich
1   University of Louisville Adult Reconstruction Program, Louisville, Kentucky
,
Kenneth G. W. MacKinlay
1   University of Louisville Adult Reconstruction Program, Louisville, Kentucky
,
Langan S. Smith
2   Kentucky One Health, Jewish Physician Group, Louisville, Kentucky
,
Arthur L. Malkani
1   University of Louisville Adult Reconstruction Program, Louisville, Kentucky
› Author Affiliations
Further Information

Publication History

14 November 2016

02 May 2017

Publication Date:
22 June 2017 (online)

Abstract

Alignment after total knee arthroplasty (TKA) plays an important role with respect to patient satisfaction and implant survivorship. In patients undergoing ipsilateral TKA with prior total hip arthroplasty (THA), the femoral intramedullary (IM) guide cannot be fully inserted into the femoral canal because of the prior THA. The purpose of this study was to determine the effect of femoral component alignment using a shorter IM guide during TKA in patients with an ipsilateral THA. We identified 42 patients undergoing ipsilateral TKA with the use of a short IM guide in the setting of a prior THA. A matched cohort group was identified from our total joint registry that included 42 patients who underwent primary TKA. The surgical goal was to achieve 5 degrees of valgus on the femoral side and 0 degree on the tibial side with an overall postoperative tibial–femoral angle of 5 degrees of valgus. Patients were evaluated clinically using Knee Society pain scores (KSSs), function scores, and with radiography. Both the tibial–femoral limb alignment and the femoral component alignment were compared using Student's t-test. There were no significant differences between the two groups with respect to sex, age, body mass index (BMI), pre- and postoperative KSSs. There was a statistically significant difference between the two groups with respect to radiographic tibial–femoral limb alignment, 4.33 degrees of valgus in the short stem THA–TKA group versus 5.4 degrees of valgus in the TKA group (p < 0.04); however, this difference did not correlate to a difference in postoperative outcomes. An adequate tibial–femoral component alignment was achieved in patients undergoing ipsilateral TKA with prior THA using a shortened IM femoral guide.

 
  • References

  • 1 Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 1994; (299) 153-156
  • 2 McGrory JE, Trousdale RT, Pagnano MW, Nigbur M. Preoperative hip to ankle radiographs in total knee arthroplasty. Clin Orthop Relat Res 2002; (404) 196-202
  • 3 Berend ME, Ritter MA, Meding JB. , et al. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 2004; (428) 26-34
  • 4 Choong PF, Dowsey MM, Stoney JD. Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 2009; 24 (04) 560-569
  • 5 Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 2010; 92 (12) 2143-2149
  • 6 Swank ML, Alkire M, Conditt M, Lonner JH. Technology and cost-effectiveness in knee arthroplasty: computer navigation and robotics. Am J Orthop 2009; 38 (2 Suppl): 32-36
  • 7 Roh YW, Kim TW, Lee S, Seong SC, Lee MC. Is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res 2013; 471 (12) 3988-3995
  • 8 Burnett RS, Barrack RL. Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res 2013; 471 (01) 264-276
  • 9 Stronach BM, Pelt CE, Erickson J, Peters CL. Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res 2013; 471 (01) 169-174
  • 10 Stronach BM, Pelt CE, Erickson JA, Peters CL. Patient-specific instrumentation in total knee arthroplasty provides no improvement in component alignment. J Arthroplasty 2014; 29 (09) 1705-1708