Subscribe to RSS
DOI: 10.1055/s-0037-1599791
Long Volar Plating for Metadiaphyseal Fractures of Distal Radius: Study Comparing Minimally Invasive Plate Osteosynthesis versus Conventional Approach
Publication History
22 October 2016
30 January 2017
Publication Date:
16 March 2017 (online)
Abstract
Background Minimally invasive plate osteosynthesis (MIPO) has been used in wrist surgery for several years. The purpose of this retrospective study was to compare clinical and radiologic outcomes of MIPO technique with those of a conventional approach in the treatment of metadiaphyseal distal radius fracture by long volar plating.
Materials and Methods Our series consisted of 32 fractures in 31 patients, mean age 63.9 years, including 16 men and 15 women. MIPO technique was used in 15 wrists (group 1) and conventional approach (> 60 mm of skin incision) in 17 wrists (group 2). In group 1, a long volar plate was inserted under pronator quadratus through a 15- to 30-mm distal incision then fixed to the epiphysis of the distal radius. Then, through a 15- to 30-mm proximal incision, the plate was fixed to the diaphysis of the radius, thus reducing the fracture.
Results In group 1, mean distal incision size was 23.5 and 16.9 mm for proximal one. Mean total scar size (sum of both distal and proximal incisions) was 40.0 mm in group 1 and 84.1 mm in group 2. Mean tourniquet time was 58.4 minutes in group 1 and 68.9 minutes in group 2. At latest follow-up, no significant difference was noted in both the groups concerning pain, quick-DASH score, grip strength, ROM, and radiologic data. One extensor pollicis longus rupture treated by tendon transfer was done in group 1.
Conclusion The MIPO technique for metadiaphyseal fractures of the distal radius by long volar plating has cosmetic and economic advantages compared with the conventional approach. Conversion to conventional approach is possible at any time in case of technical difficulties.
Level of Evidence III.
Keywords
fractures - minimally invasive plate osteosynthesis - distal radius - mini-invasive - long plate - metadiaphyseal fractureNote
This work was performed at the Department of Hand Surgery, Strasbourg University Hospitals, FMTS, Strasbourg University, Illkirch, France.
-
References
- 1 Krettek C, Schandelmaier P, Miclau T, Tscherne H. Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury 1997; 28 (Suppl. 01) A20-A30
- 2 Kim JJ, Oh HK, Bae JY, Kim JW. Radiological assessment of the safe zone for medial minimally invasive plate osteosynthesis in the distal femur with computed tomography angiography. Injury 2014; 45 (12) 1964-1969
- 3 Bhat R, Wani MM, Rashid S, Akhter N. Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on 25 patients. Eur J Orthop Surg Traumatol 2015; 25 (03) 563-568
- 4 Pires RE, Mauffrey C, de Andrade MA. , et al. Minimally invasive percutaneous plate osteosynthesis for ankle fractures: a prospective observational cohort study. Eur J Orthop Surg Traumatol 2014; 24 (07) 1297-1303
- 5 Gao YB, Tong SL, Yu JH, Lu WJ. [Case control study on open reduction internal fixation (ORIF) and minimally invasive percutaneous plate osteosynthesis (MIPPO) for the treatment of proximal humerus fractures in aged] [in Chinese]. Zhongguo Gu Shang 2015; 28 (04) 335-339
- 6 Zhang Y, Xu J, Zhang C, Sun Y. Minimally invasive plate osteosynthesis for midshaft clavicular fractures using superior anatomic plating. J Shoulder Elbow Surg 2016; 25 (01) e7-e12
- 7 Zogbi DR, Terrivel AM, Mouraria GG, Mongon ML, Kikuta FK, Filho AZ. Fracture of distal humerus: MIPO technique with visualization of the radial nerve. Acta Ortop Bras 2014; 22 (06) 300-303
- 8 Helfet DL, Shonnard PY, Levine D, Borrelli Jr J. Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 1997; 28 (Suppl. 01) A42-A47 , discussion A47–A48
- 9 Wagner M. General principles for the clinical use of the LCP. Injury 2003; 34 (Suppl. 02) B31-B42
- 10 Agee JM. Distal radius fractures. Multiplanar ligamentotaxis. Hand Clin 1993; 9 (04) 577-585
- 11 Geissler WB, Fernandes D. Percutaneous and limited open reduction of intra-articular distal radial fractures. Hand Surg 2000; 5 (02) 85-92
- 12 Imatani J, Noda T, Morito Y, Sato T, Hashizume H, Inoue H. Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg [Br] 2005; 30 (02) 220-225
- 13 Yoshikawa Y, Saito T, Matsui H. , et al. A new cosmetic approach for volar fixed-angle plate fixation to treat distal radius fractures. J Jpn Soc Surg Hand. 2008; 24: 889-893
- 14 Sen MK, Strauss N, Harvey EJ. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg 2008; 12 (01) 2-6
- 15 Zenke Y, Sakai A, Oshige T. , et al. Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma 2011; 25 (07) 425-431
- 16 Abe Y, Yoshida K, Tominaga Y. Less invasive surgery with wrist arthroscopy for distal radius fracture. J Orthop Sci 2013; 18 (03) 398-404
- 17 Zemirline A, Naito K, Lebailly F, Facca S, Liverneaux P. Distal radius fixation through a mini-invasive approach of 15 mm. Part 1: feasibility study. Eur J Orthop Surg Traumatol 2014; 24 (06) 1031-1037
- 18 Rey PB, Rochet S, Loisel F, Obert L. Technical note: how to spare the pronator quadratus during MIPO of distal radius fractures by using a mini-volar plate. Chir Main 2014; 33 (02) 95-99
- 19 Lebailly F, Zemirline A, Facca S, Gouzou S, Liverneaux P. Distal radius fixation through a mini-invasive approach of 15 mm. PART 1: a series of 144 cases. Eur J Orthop Surg Traumatol 2014; 24 (06) 877-890
- 20 Wei XM, Sun ZZ, Rui YJ, Song XJ, Jiang WM. Minimally invasive percutaneous plate osteosynthesis for distal radius fractures with long-segment metadiaphyseal comminution. Orthop Traumatol Surg Res 2016; 102 (03) 333-338
- 21 Chmielnicki M, Prokop A. [New minimally invasive approach for palmar plating in distal radius fractures] [in Chinese]. Z Orthop Unfall 2015; 153 (01) 25-28
- 22 Wei XM, Sun ZZ, Rui YJ, Song XJ. Minimally invasive plate osteosynthesis for distal radius fractures. Indian J Orthop 2014; 48 (01) 20-24
- 23 Chen CY, Lin KC, Yang SW, Renn JH, Tarng YW. Clinical results of using minimally invasive long plate osteosynthesis versus conventional approach for extensive comminuted metadiaphyseal fractures of the radius. Arch Orthop Trauma Surg 2015; 135 (03) 361-367
- 24 Henry AK. Extensile Exposures. Vol 1. Edinburgh, UK: Churchill Livingston; 1957
- 25 Heim U, Pfeiffer KM. Internal Fixation of Small Fractures. 3rd ed. Vol 1. Berlin, Germany: Springer Verlag; 1987
- 26 Duncan SF, Weiland AJ. Minimally invasive reduction and osteosynthesis of articular fractures of the distal radius. Injury 2001; 32 (Suppl. 01) SA14-SA24
- 27 Gutierrez Olivera N, Ruchelli L, Iglesias S, Capomassi M, Allende C. Minimally invasive plate osteosynthesis in distal radius fractures with metaphyseal extension: a series of 13 cases. Chir Main 2015; 34 (05) 227-233
- 28 Zemirline A, Taleb C, Facca S, Liverneaux P. Minimally invasive surgery of distal radius fractures: a series of 20 cases using a 15mm anterior approach and arthroscopy. Chir Main 2014; 33 (04) 263-271