Semin intervent Radiol 2015; 32(04): 374-378
DOI: 10.1055/s-0035-1564792
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Venous Thromboembolic Disease: The Use of the Aspiration Thrombectomy Device AngioVac

George Behrens
1   Department of Interventional Radiology, VIR Chicago at Hinsdale Adventist Hospital, Hinsdale, Illinois
,
Haraldur Bjarnason
2   Division of Interventional Radiology, Department of Radiology, Mayo Clinic, Rochester, Minnesota
› Author Affiliations
Further Information

Publication History

Publication Date:
10 November 2015 (online)

Abstract

Central venous thrombosis is a complex problem, particularly in cases where the thrombus burden is large. Several interventional techniques and devices have been developed over the past 15 to 20 years to manage this entity, but the vast majority of them still need the concomitant use of thrombolytics to achieve an optimal result. AngioVac (AngioDynamics, Latham, NY) is the first aspiration thrombectomy device capable to remove a larger burden of undesired intravascular material such as thrombus, tumor, and foreign bodies without the need of lytics. This review focuses on the AngioVac device in the management of iliocaval thrombosis and pulmonary embolism.

 
  • References

  • 1 Parikh S, Motarjeme A, McNamara T , et al. Ultrasound-accelerated thrombolysis for the treatment of deep vein thrombosis: initial clinical experience. J Vasc Interv Radiol 2008; 19 (4) 521-528
  • 2 Vedantham S, Vesely TM, Sicard GA , et al. Pharmacomechanical thrombolysis and early stent placement for iliofemoral deep vein thrombosis. J Vasc Interv Radiol 2004; 15 (6) 565-574
  • 3 Lin PH, Zhou W, Dardik A , et al. Catheter-direct thrombolysis versus pharmacomechanical thrombectomy for treatment of symptomatic lower extremity deep venous thrombosis. Am J Surg 2006; 192 (6) 782-788
  • 4 Arko FR, Davis III CM, Murphy EH , et al. Aggressive percutaneous mechanical thrombectomy of deep venous thrombosis: early clinical results. Arch Surg 2007; 142 (6) 513-518 , discussion 518–519
  • 5 Kim HS, Patra A, Paxton BE, Khan J, Streiff MB. Catheter-directed thrombolysis with percutaneous rheolytic thrombectomy versus thrombolysis alone in upper and lower extremity deep vein thrombosis. Cardiovasc Intervent Radiol 2006; 29 (6) 1003-1007
  • 6 Smith SJ, Behrens G, Sewall LE, Sichlau MJ. Vacuum-assisted thrombectomy device (AngioVac) in the management of symptomatic iliocaval thrombosis. J Vasc Interv Radiol 2014; 25 (3) 425-430
  • 7 Dudiy Y, Kronzon I, Cohen HA, Ruiz CE. Vacuum thrombectomy of large right atrial thrombus. Catheter Cardiovasc Interv 2012; 79 (2) 344-347
  • 8 Sengodan P, Grewal H, Gandhi S. Invasive hepatocellular carcinoma with recurrent pulmonary embolism: use of AngioVac cannula thrombectomy device for mechanical aspiration. J Invasive Cardiol 2014; 26 (7) E100-E103
  • 9 Patel N, Azemi T, Zaeem F , et al. Vacuum assisted vegetation extraction for the management of large lead vegetations. J Card Surg 2013; 28 (3) 321-324
  • 10 Pasha AK, Elder MD, Khurram D, Snyder BA, Movahed MR. Successful management of acute massive pulmonary embolism using Angiovac suction catheter technique in a hemodynamically unstable patient. Cardiovasc Revasc Med 2014; 15 (4) 240-243
  • 11 Chin AK, Aklog L, deGuzman BJ, Glennon M. Application of a novel venous cannula for en-bloc removal of undesirable intravascular material. In: Narin C, (Ed.) Special Topics in Cardiac Surgery. InTech Rijeka Croatia; 2012: 127-142
  • 12 Giordano P, Weber K, Davis M, Carter E. Acute thrombosis of the inferior vena cava. Am J Emerg Med 2006; 24 (5) 640-642
  • 13 Ahmad I, Yeddula K, Wicky S, Kalva SP. Clinical sequelae of thrombus in an inferior vena cava filter. Cardiovasc Intervent Radiol 2010; 33 (2) 285-289
  • 14 McAree BJ, O'Donnell ME, Fitzmaurice GJ, Reid JA, Spence RA, Lee B. Inferior vena cava thrombosis: a review of current practice. Vasc Med 2013; 18 (1) 32-43
  • 15 Donaldson CW, Baker JN, Narayan RL , et al. Thrombectomy using suction filtration and veno-venous bypass: Single center experience with a novel device. Catheter Cardiovasc Interv 2015; 86 (2) E81-E87