Thorac Cardiovasc Surg 2016; 64(05): 434-440
DOI: 10.1055/s-0035-1563539
Original Cardiovascular
Georg Thieme Verlag KG Stuttgart · New York

Is a Profiled Annuloplasty Ring Suitable for Repair of Degenerative Mitral Regurgitation? A Single-Center Experience Comprising 200 Patients

Ralf Guenzinger*
1   Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Munich, Germany
,
Thomas Guenther*
1   Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Munich, Germany
,
Thomas Ratschiller
1   Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Munich, Germany
,
Kathrin Minkner
1   Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Munich, Germany
,
Ina-Christine Rondak
2   Technische Universität München, Institute of Medical Statistics and Epidemiology, Munich, Germany
,
Bernhard Voss
1   Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Munich, Germany
,
Ruediger Lange
1   Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Munich, Germany
3   Partner Site Munich Heart Alliance, DZHK (German Center for Cardiovascular Research), Munich, Germany
› Author Affiliations
Further Information

Publication History

04 May 2015

01 June 2015

Publication Date:
03 September 2015 (online)

Abstract

Background Various devices have been proposed for ring annuloplasty in patients with degenerative mitral valve disease. This study reports for the first time midterm results with the rigid three-dimensional Medtronic Profile 3D (Medtronic, Minneapolis, Minnesota, United States) annuloplasty ring.

Methods Between June 2009 and June 2011, 200 patients (mean age 61 ± 13 years, 70% male) with severe degenerative mitral regurgitation underwent mitral valve repair using the Medtronic Profile 3D annuloplasty ring. A total of 106 patients (53.0%) underwent isolated mitral valve repair and 94 patients (47.0%) underwent a concomitant procedure such as coronary artery bypass grafting (n = 21), tricuspid valve surgery (n = 49), AF ablation (n = 17), and aortic valve surgery (n = 13). The follow-up is 94.5% complete (mean 2.5 ± 0.5 years).

Results Thirty-day mortality was 1.5%. Survival at 3 years was 97.1 ± 1.6% for isolated procedures and 92.4 ± 2.8% for combined procedures (p = 0.137). Freedom from mitral valve–related reoperation at 3 years was 97.1 ± 1.7% for isolated procedures and 95.5 ± 2.2% for combined procedures (p = 0.561). Seven patients (3.5%) required a mitral valve–related reoperation. Two of these reoperations were required for endocarditis, two for ring dehiscence, one for progression of the native disease (flail leaflet), one for leaflet suture dehiscence, and one for persistent systolic anterior motion.

Conclusion The three-dimensional Medtronic Profile 3D annuloplasty ring is suitable for mitral valve repair for degenerative diseases. This saddle-shaped annuloplasty device provides excellent early results with a very good functional outcome at midterm either in isolated or combined procedures.

Note

Parts of the data were presented at the 43rd Meeting of the German Society for Thoracic and Cardiovascular Surgery in Freiburg (Germany) in February 2014.


* These authors contributed equally to the manuscript.


 
  • References

  • 1 Gillinov AM, Mihaljevic T, Blackstone EH , et al. Should patients with severe degenerative mitral regurgitation delay surgery until symptoms develop?. Ann Thorac Surg 2010; 90 (2) 481-488
  • 2 David TE, Armstrong S, McCrindle BW, Manlhiot C. Late outcomes of mitral valve repair for mitral regurgitation due to degenerative disease. Circulation 2013; 127 (14) 1485-1492
  • 3 Carpentier AF, Lessana A, Relland JY , et al. The “physio-ring”: an advanced concept in mitral valve annuloplasty. Ann Thorac Surg 1995; 60 (5) 1177-1185 , discussion 1185–1186
  • 4 Nardi P, Pellegrino A, Olevano C , et al. Mitral valve repair for the treatment of degenerative mitral valve disease with or without prosthetic ring annuloplasty: long-term outcomes. J Cardiovasc Surg (Torino) 2013; 54 (2) 305-312
  • 5 Flameng W, Herijgers P, Bogaerts K. Recurrence of mitral valve regurgitation after mitral valve repair in degenerative valve disease. Circulation 2003; 107 (12) 1609-1613
  • 6 Sharony R, Saunders PC, Nayar A , et al. Semirigid partial annuloplasty band allows dynamic mitral annular motion and minimizes valvular gradients: an echocardiographic study. Ann Thorac Surg 2004; 77 (2) 518-522 , discussion 522
  • 7 Cosgrove III DM, Arcidi JM, Rodriguez L, Stewart WJ, Powell K, Thomas JD. Initial experience with the cosgrove-edwards annuloplasty system. Ann Thorac Surg 1995; 60 (3) 499-503 , discussion 503–504
  • 8 Levine RA, Triulzi MO, Harrigan P, Weyman AE. The relationship of mitral annular shape to the diagnosis of mitral valve prolapse. Circulation 1987; 75 (4) 756-767
  • 9 Salgo IS, Gorman III JH, Gorman RC , et al. Effect of annular shape on leaflet curvature in reducing mitral leaflet stress. Circulation 2002; 106 (6) 711-717
  • 10 Ryan LP, Jackson BM, Enomoto Y , et al. Description of regional mitral annular nonplanarity in healthy human subjects: a novel methodology. J Thorac Cardiovasc Surg 2007; 134 (3) 644-648
  • 11 Zoghbi WA, Enriquez-Sarano M, Foster E , et al; American Society of Echocardiography. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. J Am Soc Echocardiogr 2003; 16 (7) 777-802
  • 12 Mahmood F, Gorman III JH, Subramaniam B , et al. Changes in mitral valve annular geometry after repair: saddle-shaped versus flat annuloplasty rings. Ann Thorac Surg 2010; 90 (4) 1212-1220
  • 13 Ryomoto M, Mitsuno M, Yamamura M , et al. Is physiologic annular dynamics preserved after mitral valve repair with rigid or semirigid ring?. Ann Thorac Surg 2014; 97 (2) 492-497
  • 14 Jensen MO, Jensen H, Levine RA , et al. Saddle-shaped mitral valve annuloplasty rings improve leaflet coaptation geometry. J Thorac Cardiovasc Surg 2011; 142 (3) 697-703
  • 15 Vergnat M, Jackson BM, Cheung AT , et al. Saddle-shape annuloplasty increases mitral leaflet coaptation after repair for flail posterior leaflet. Ann Thorac Surg 2011; 92 (3) 797-803
  • 16 Vohra HA, Whistance RN, Bezuska L, Livesey SA. Initial experience of mitral valve repair using the Carpentier-Edwards Physio II annuloplasty ring. Eur J Cardiothorac Surg 2011; 39 (6) 881-885
  • 17 van Rijk-Zwikker GL, Delemarre BJ, Huysmans HA. Mitral valve anatomy and morphology: relevance to mitral valve replacement and valve reconstruction. J Card Surg 1994; 9 (2, Suppl): 255-261
  • 18 Perier P, Hohenberger W, Lakew F , et al. Toward a new paradigm for the reconstruction of posterior leaflet prolapse: midterm results of the “respect rather than resect” approach. Ann Thorac Surg 2008; 86 (3) 718-725 , discussion 718–725
  • 19 Jimenez JH, Soerensen DD, He Z, He S, Yoganathan AP. Effects of a saddle shaped annulus on mitral valve function and chordal force distribution: an in vitro study. Ann Biomed Eng 2003; 31 (10) 1171-1181
  • 20 Jassar AS, Vergnat M, Jackson BM , et al. Regional annular geometry in patients with mitral regurgitation: implications for annuloplasty ring selection. Ann Thorac Surg 2014; 97 (1) 64-70
  • 21 Lee AP, Hsiung MC, Salgo IS , et al. Quantitative analysis of mitral valve morphology in mitral valve prolapse with real-time 3-dimensional echocardiography: importance of annular saddle shape in the pathogenesis of mitral regurgitation. Circulation 2013; 127 (7) 832-841
  • 22 Pfannmüller B, Seeburger J, Misfeld M, Borger MA, Garbade J, Mohr FW. Minimally invasive mitral valve repair for anterior leaflet prolapse. J Thorac Cardiovasc Surg 2013; 146 (1) 109-113
  • 23 Seeburger J, Falk V, Borger MA , et al. Chordae replacement versus resection for repair of isolated posterior mitral leaflet prolapse: à ègalité. Ann Thorac Surg 2009; 87 (6) 1715-1720
  • 24 Zegdi R, Sleilaty G, Latrémouille C , et al. Reoperation for failure of mitral valve repair in degenerative disease: a single-center experience. Ann Thorac Surg 2008; 86 (5) 1480-1484
  • 25 van Rijk-Zwikker GL, Mast F, Schipperheyn JJ, Huysmans HA, Bruschke AV. Comparison of rigid and flexible rings for annuloplasty of the porcine mitral valve. Circulation 1990; 82 (5, Suppl): IV58-IV64
  • 26 Salvador L, Mirone S, Bianchini R , et al. A 20-year experience with mitral valve repair with artificial chordae in 608 patients. J Thorac Cardiovasc Surg 2008; 135 (6) 1280-1287