Subscribe to RSS
DOI: 10.1055/s-0034-1391125
Endoscopic ultrasonography-guided liver abscess drainage using a dedicated, wide, fully covered self-expandable metallic stent with flared-ends
Publication History
Publication Date:
19 December 2014 (online)
Endoscopic ultrasonography (EUS)-guided drainage of liver abscesses has recently become available. We present here a case of successful drainage of a liver abscess using a dedicated wide fully covered self-expandable metallic stent (FCSEMS) with flared ends.
An 84-year-old man was admitted to another hospital with a history of high fever and epigastric pain for 12 days. Computed tomography (CT) revealed a 10.3 × 6.1-cm abscess in the left lobe of the liver ([Fig. 1]). He was referred to our hospital because of failure of a 1-week antibiotic regimen. Esophagogastroduodenoscopy revealed a bulging mass in the stomach ([Fig. 2]).
We attempted EUS-guided drainage through a transgastric approach. Using a 19-gauge needle, we punctured the abscess and placed a 0.025-inch guidewire ([Fig. 3]). A 6-Fr wire-guided diathermic dilator (Cysto-Gastro-Set; Endo-Flex, Voerde, Germany) was used to dilate the needle tract using a blended cut mode. Finally, a dedicated wide FCSEMS with flared ends (NAGI stent, 16 × 3 cm; Taewoong-Medical, Seoul, Korea) was placed, without any complications ([Fig. 4], [Fig. 5]). After stone clearance from the common bile duct, the patient was discharged on postoperative day 10 without removal of the SEMS ([Fig. 6]).
Seven cases of EUS-guided drainage of liver abscess, including one case of multiple abscesses, have been reported to date [1] [2]. The left lobe of the liver, the caudate lobe, and the gastrohepatic space usually lie in close proximity to the stomach or duodenum [1]. Therefore, EUS-guided liver abscess drainage might be safe and effective in the management of these areas. Single or double plastic stents were used in most of the reported cases [1]; the newly designed dedicated anchoring FCSEMS with a “yo-yo” shape was placed in only one patient [2]. It has been suggested that a dedicated FCSEMS is the ideal stent for treating liver abscesses and pancreatic fluid collection because of its antimigration feature and because it allows direct insertion of an endoscope through it [3].
Endoscopy_UCTN_Code_TTT_1AS_2AC
-
References
- 1 Singhal S, Changela K, Lane D et al. Endoscopic ultrasound-guided hepatic and perihepatic abscess drainage: an evolving technique. Therap Adv Gastroenterol 2014; 7: 93-98
- 2 Alcaide N, Vargas-Garcia AL, de la Serna-Higuera C et al. EUS-guided drainage of liver abscess by using a lumen-apposing metal stent (with video). Gastrointest Endosc 2013; 78: 941-942
- 3 Kawakami H, Itoi T, Sakamoto N. Endoscopic ultrasound-guided transluminal drainage for peripancreatic fluid collections: Where we are now?. Gut Liver 2014; 8: 341-355