CC BY-NC-ND 4.0 · Endosc Int Open 2021; 09(06): E895-E900
DOI: 10.1055/a-1399-8442
Original article

Endoscopic ultrasound-guided gastroenterostomy using large-diameter (20 mm) lumen apposing metal stent (LLAMS)

Zain A. Sobani
Division of Gastroenterology and Hepatology, University of New Mexico, Albuquerque, New Mexico, United States
,
Swathi Paleti
Division of Gastroenterology and Hepatology, University of New Mexico, Albuquerque, New Mexico, United States
,
Tarun Rustagi
Division of Gastroenterology and Hepatology, University of New Mexico, Albuquerque, New Mexico, United States
› Author Affiliations

Abstract

Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a 15-mm lumen apposing metal stent (LAMS) has emerged as a viable alternative to surgical gastrojejunostomy for management of gastric outlet obstruction (GOO). However, given the size of the anastomosis created with a 15-mm LAMS, long-term luminal patency and clinical outcomes may be suboptimal. The aim of this study was to evaluate the technical feasibility, efficacy, and safety of EUS-GE with a large-diameter (20 mm) LAMS (LLAMS).

Patients and methods A retrospective analysis of a prospectively maintained database of all patients undergoing EUS-GE with LLAMS between December 1, 2018 and September 30, 2020 was performed. All EUS-GEs were performed using a cautery-enhanced LLAMS.

Results Thirty-three patients were referred for endoscopic management of GOO. Two patients were excluded due to a lack of an adequate window for EUS-GE. The remaining 31 patients (93.94 %) (mean age: 61.35 ± 16.52 years; 54.84 % males) underwent EUS-GE using LLAMS for malignant (n = 23) and benign (n = 8) GOO. Technical success was achieved in all patients (100 %) with attempted EUS-GE. Complete clinical success (tolerance of regular diet) was achieved in 93.55 % of patients (n = 29). Two patients (6.45 %) had partial clinical success and died of unrelated causes prior to advancing diet beyond full liquids. Overall mean follow-up was 140.84 ± 160.41 days (median 70, range 4–590). All stents remained patent with no evidence of recurrent GOO symptoms. One patient (3.23 %) developed an asymptomatic clean-based jejunal ulcer on 3-month follow-up endoscopy.

Conclusions EUS-GE with LLAMS is a technically feasible, effective and safe option for patients with GOO allowing for tolerability of regular diet. Future prospective, ideally randomized studies comparing long-term outcomes of EUS-GE with 20- and 15-mm LAMS are required.



Publication History

Received: 14 December 2020

Accepted: 15 February 2021

Article published online:
27 May 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Jeurnink SM, Steyerberg EW, van Hooft JE. et al. Surgical gastrojejunostomy or endoscopic stent placement for the palliation of malignant gastric outlet obstruction (SUSTENT study): a multicenter randomized trial. Gastrointest Endosc 2010; 71: 490-499
  • 2 Itoi T, Baron TH, Khashab MA. et al. Technical review of endoscopic ultrasonography-guided gastroenterostomy in 2017. Dig Endosc 2017; 29: 495-502
  • 3 Khashab M, Alawad AS, Shin EJ. et al. Enteral stenting versus gastrojejunostomy for palliation of malignant gastric outlet obstruction. Surg Endosc 2013; 27: 2068-2075
  • 4 Heo J, Jung MK. Safety and efficacy of a partially covered self-expandable metal stent in benign pyloric obstruction. World J Gastroenterol 2014; 20: 16721-16725
  • 5 Kang HW, Kim SG. Upper gastrointestinal stent insertion in malignant and benign disorders. Clin Endosc 2015; 48: 187-193
  • 6 McCarty TR, Garg R, Thompson CC. et al. Efficacy and safety of EUS-guided gastroenterostomy for benign and malignant gastric outlet obstruction: a systematic review and meta-analysis. Endosc Int Open 2019; 7: E1474-E1482
  • 7 Iqbal U, Khara HS, Hu Y. et al. EUS-guided gastroenterostomy for the management of gastric outlet obstruction: A systematic review and meta-analysis. Endosc Ultrasound 2020; 9: 16-23
  • 8 Cotton PB, Eisen GM, Aabakken L. et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010; 71: 446-454
  • 9 Fritscher-Ravens A, Mosse CA, Mills TN. et al. A through-the-scope device for suturing and tissue approximation under EUS control. Gastrointest Endosc 2002; 56: 737-742
  • 10 Rimbas M, Larghi A, Costamagna G. Endoscopic ultrasound-guided gastroenterostomy: Are we ready for prime time?. Endosc Ultrasound 2017; 6: 235-240
  • 11 Itoi T, Binmoeller KF, Shah J. et al. Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos). Gastrointest Endosc 2012; 75: 870-876
  • 12 Tringali A, Giannetti A, Adler DG. Endoscopic management of gastric outlet obstruction disease. Ann Gastroenterol 2019; 32: 330-337
  • 13 Itoi T, Itokawa F, Uraoka T. et al. Novel EUS-guided gastrojejunostomy technique using a new double-balloon enteric tube and lumen-apposing metal stent (with videos). Gastrointest Endosc 2013; 78: 934-939
  • 14 Itoi T, Ishii K, Ikeuchi N. et al. Prospective evaluation of endoscopic ultrasonography-guided double-balloon-occluded gastrojejunostomy bypass (EPASS) for malignant gastric outlet obstruction. Gut 2016; 65: 193-195
  • 15 Chen YI, James TW, Agarwal A. et al. EUS-guided gastroenterostomy in management of benign gastric outlet obstruction. Endosc Int Open 2018; 6: E363-E368
  • 16 Kastelijn JB, Moons LMG, Garcia-Alonso FJ. et al. Patency of endoscopic ultrasound-guided gastroenterostomy in the treatment of malignant gastric outlet obstruction. Endosc Int Open 2020; 8: E1194-E1201
  • 17 James TW, Greenberg S, Grimm IS. et al. EUS-guided gastroenteric anastomosis as a bridge to definitive treatment in benign gastric outlet obstruction. Gastrointest Endosc 2020; 91: 537-542
  • 18 Madanat L, Saumoy M, Sharaiha RZ. Endoscopic gastrojejunostomy - bigger is better. Endoscopy 2018; 50: E331-E332
  • 19 Adler DG, Mallery S, Amateau S. et al. A pilot study of a 20-mm lumen-apposing metal stent to treat pancreatic fluid collections: First reported multicenter use of a new device. Endosc Ultrasound 2019; 8: 136-138
  • 20 Parsa N, Nieto JM, Powers P. et al. Endoscopic ultrasound-guided drainage of pancreatic walled-off necrosis using 20-mm versus 15-mm lumen-apposing metal stents: an international, multicenter, case-matched study. Endoscopy 2020; 52: 211-219
  • 21 Krafft MR, Hsueh W, James TW. et al. The EDGI new take on EDGE: EUS-directed transgastric intervention (EDGI), other than ERCP, for Roux-en-Y gastric bypass anatomy: a multicenter study. Endosc Int Open 2019; 7: E1231-E1240
  • 22 Tyberg A, Kedia P, Tawadros A. et al. EUS-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE): the first learning curve. J Clin Gastroenterol 2020; 54: 569-572
  • 23 James HJ, James TW, Wheeler SB. et al. Cost-effectiveness of endoscopic ultrasound-directed transgastric ERCP compared with device-assisted and laparoscopic-assisted ERCP in patients with Roux-en-Y anatomy. Endoscopy 2019; 51: 1051-1058
  • 24 Taibi A, Durand Fontanier S. et al. What is the ideal indwelling time for metal stents after endoscopic ultrasound-guided gastrojejunostomy? Case report of delayed iatrogenic perforation with a review of the literature. Dig Endosc 2020; 32: 816-822