Transfer of a lumen-apposing metal stent to a different fistula for endoscopic necrosectomy of walled-off pancreatic necrosis
A 54-year-old man underwent multiple rounds of endoscopic necrosectomy via a 15-mm-diameter lumen-apposing metal stent (LAMS) (Hot AXIOS; Boston Scientific, Marlborough, MA, USA) in the gastric body for a large walled-off pancreatic necrosis (WON); however, infectious WON remained ([Fig. 1]). Endoscopic ultrasound-guided transmural drainage with a plastic stent through the antrum was performed. Because of the unstable position of the echoendoscope, a LAMS was not used. Endoscopic necrosectomy was attempted 6 days later, but scope insertion through the antrum fistula was difficult. Thus, we attempted to transfer the LAMS from the gastric body to the antrum fistula.
The distal flange of the LAMS removed from the gastric body was grasped with 20-mm snare forceps through one channel of a two-channel endoscope. The manually compressed proximal flange was retrogradely inserted into the other channel ([Fig. 2]). The scope was inserted into the WON, and the distal flange was released into the cavity first. Next, the scope was gradually withdrawn, and an attempt was made to push the LAMS using forceps to release the proximal flange into the gastric lumen. However, the proximal flange was unintentionally released into the WON. A conventional endoscope was then inserted into the WON, and the proximal flange was successfully withdrawn into the gastric lumen by grasping the proximal flange with forceps. The LAMS placement facilitated smooth scope insertion into the WON. Finally, for fistula maintenance, the plastic stent removed from the antrum fistula was redeployed to the body fistula ([Fig. 3], [Video 1]).
Video 1 Deployment of a lumen-apposing metal stent to a different fistula using a two-channel endoscope.
Qualität:
Although the removal and replacement of the same LAMS have been reported recently [1] [2] [3], there have been no reports of LAMS transfer to another fistula for endoscopic necrosectomy. This case suggests that endoscopic necrosectomy from multiple fistulas with a single LAMS is possible by transferring the LAMS to another fistula with placement of a plastic stent.
Endoscopy_UCTN_Code_CPL_1AL_2AD
Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.
This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos
Publikationsverlauf
Artikel online veröffentlicht:
27. Januar 2021
© 2021. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Guarner AC, Colán-Hernández J, Concepción-Martín M. et al. Replacement of the same lumen-apposing metallic stent for multiple necrosectomy sessions. Endoscopy 2015; 47: E447-E448
- 2 Yoshida M, Naitoh I, Yamada R. et al. On-and-off deployment technique of a lumen-apposing metal stent during endoscopic pancreatic necrosectomy. Endoscopy 2020; 52: E158-E159
- 3 Gulati R, Rustagi T. Endoscopic removal and replacement of the same lumen-apposing metal stent for multiple endoscopic necrosectomy sessions (with video). Endoscopy 2020; DOI: 10.1055/a-1192-3219.