Subscribe to RSS
DOI: 10.1055/a-1014-2593
Prediction of Adnexal Torsion by Ultrasound in Women with Acute Abdominal Pain
Vorhersage der Adnextorsion mittels Ultraschalls bei Frauen mit akuten UnterbauchschmerzenPublication History
09 April 2019
03 September 2019
Publication Date:
08 November 2019 (online)
Abstract
Purpose To investigate the accuracy of ultrasound in the diagnosis of adnexal torsion.
Materials and Methods Retrospective cohort analysis of 322 women, presenting to a tertiary medical center with acute abdominal pain, who underwent gynecological examination, sonographic evaluation and laparoscopic surgery, between 2010 and 2016. Findings for adnexal torsion were compared among three groups: positive sonographic findings consistent with surgically confirmed adnexal torsion (true positive, n = 228); negative sonographic findings inconsistent with surgically confirmed adnexal torsion (false negative, n = 42); and positive sonographic findings inconsistent with a surgical diagnosis other than adnexal torsion (false positive, n = 52). Outcome measures were sensitivity and positive predictive value of ultrasound, and its specific features, for the diagnosis of adnexal torsion.
Results The sensitivity of ultrasound for adnexal torsion diagnosis was 84.4 %, and the positive predictive value was 81.4 %. Edematous ovary and/or tube, as well as positive whirlpool sign had the highest sensitivity and positive predictive value. The false-negative group had the highest frequency of ovarian cysts (p = 0.0086) and the lowest frequency of ovarian edema (p < 0.0001). The false-positive group had the lowest proportion of pregnant women (p = 0.0022). Significantly more women in the true-positive group had a prior event of adnexal torsion (p = 0.026).
Conclusion Ultrasound examination is highly accurate in the diagnosis of adnexal torsion. Clinicians should be aware of the presence of demographic and clinical characteristics that may positively or negatively affect sonographic diagnostic accuracy.
Zusammenfassung
Ziel Untersuchung der Treffsicherheit der Sonografie bei der Diagnose der Adnextorsion.
Materialien und Methoden Retrospektive Kohortenanalyse von 322 Frauen, die zwischen 2010 und 2016 ein tertiäres medizinisches Zentrum wegen akuter Unterbauchschmerzen aufsuchten und bei denen eine gynäkologische, sonografische und laparoskopische Untersuchung durchgeführt wurde. Die Befunde, die für eine Adnextorsion sprechen, wurden in 3 Gruppen verglichen: positive sonografische Befunde in Übereinstimmung mit einer chirurgisch nachgewiesenen Adnextorsion (richtig positiv; n = 228); negative sonografische Befunde, die nicht mit der chirurgisch bestätigten Adnextorsion übereinstimmen (falsch negativ; n = 42) und positive sonografische Befunde, die nicht mit dem chirurgischen Ausschluss der Adnextorsion übereinstimmen (falsch positiv; n = 52). Als Zielgrößen wurden die Sensitivität und der positive Vorhersagewert des Ultraschalls sowie dessen spezifische Merkmale für die Diagnose der Adnextorsion bestimmt.
Ergebnisse Die Sensitivität des Ultraschalls für die Diagnose der Adnextorsion betrug 84,4 %, der positive Vorhersagewert 81,4 %. Ödeme an den Eierstöcken und/oder -tuben sowie positive „Whirlpool-Zeichen“ hatten die höchste Sensitivität und den höchsten positiven Vorhersagewert. Die Falsch-negativ-Gruppe zeigte am häufigsten Eierstockzysten (p = 0,0086) und am seltensten Eierstock-Ödeme (p < 0,0001). Die Falsch-positiv-Gruppe hatte den geringsten Anteil an schwangeren Frauen (p = 0,0022). In der Richtig-positiv-Gruppe hatten signifikant mehr Frauen bereits eine Adnextorsion durchgemacht (p = 0,026).
Schlussfolgerung Die Ultraschalluntersuchung ist bei der Diagnose der Adnextorsion äußerst treffsicher. Ärzte sollten darauf achten, ob demografische und klinische Charakteristiken vorliegen, welche die Genauigkeit der sonografischen Diagnose positiv oder negativ beeinflussen könnten.
-
References
- 1 Huchon C, Fauconnier A. Adnexal torsion: a literature review. Eur J Obstet Gynecol Reprod Biol 2010; 150: 8-12
- 2 McWilliams GD, Hill MJ, Dietrich 3rd CS. Gynecologic emergencies. Surg Clin North Am 2008; 88: 265-383
- 3 Sasaki KJ, Miller CE. Adnexal torsion: review of the literature. J Minim Invasive Gynecol 2014; 21: 196-202
- 4 Anders JF, Powell EC. Urgency of evaluation and outcome of acute ovarian torsion in pediatric patients. Arch Pediatr Adolesc Med 2005; 159: 532-535
- 5 Chiou SY, Lev-Toaff AS, Masuda E. et al. Adnexal torsion: new clinical and imaging observations by sonography, computed tomography, and magnetic resonance imaging. J Ultrasound Med 2007; 26: 1289-1301
- 6 Ashwal E, Hiersch L, Krissi H. et al. Characteristics and management of ovarian torsion in premenarchal compared with postmenarchal patients. Obstet Gynecol 2015; 126: 514-520
- 7 Bayer AI, Wiskind AK. Adnexal torsion: can the adnexa be saved?. Am J Obstet Gynecol 1994; 171: 1506-1510
- 8 Shalev E, Bustan M, Yarom I. et al. Recovery of ovarian function after laparoscopic detorsion. Hum Reprod 1995; 10: 2965-2966
- 9 Oelsner G, Cohen SB, Soriano D. et al. Minimal surgery for the twisted ischaemic adnexa can preserve ovarian function. Hum Reprod 2003; 18: 2599-2602
- 10 Malamas FM, Michala L, Chatzipapas IK. et al. Adnexal torsion: don’t give up on the ovary. J Obstet Gynaecol 2012; 32: 314-315
- 11 Graif M, Shalev J, Strauss S. et al. Torsion of the ovary: sonographic features. Am J Roentgenol 1984; 143: 1331-1334
- 12 Peña JE, Ufberg D, Cooney N. et al. Usefulness of Doppler sonography in the diagnosis of ovarian torsion. Fertil Steril 2000; 73: 1047-1050
- 13 Albayram F, Hamper UM. Ovarian and adnexal torsion: spectrum of sonographic findings with pathologic correlation. J Ultrasound Med 2001; 20: 1083-1089
- 14 Vijayaraghavan SB. Sonographic whirlpool sign in ovarian torsion. J Ultrasound Med 2004; 23: 1643-1649
- 15 Servaes S, Zurakowski D, Laufer MR. et al. Sonographic findings of ovarian torsion in children. Pediatr Radiol 2007; 37: 446-451
- 16 Shadinger LL, Andreotti RF, Kurian RL. Preoperative sonographic and clinical characteristics as predictors of ovarian torsion. J Ultrasound Med 2008; 27: 7-13
- 17 Bar-On S, Mashiach R, Stockheim D. et al. Emergency laparoscopy for suspected ovarian torsion: are we too hasty to operate?. Fertil Steril 2010; 93: 2012-2015
- 18 Mashiach R, Melamed N, Gilad N. et al. Sonographic diagnosis of ovarian torsion. J Ultrasound Med 2011; 30: 205-210
- 19 Melcer Y, Maymon R, Pekar-Zlotin M. et al. Clinical and sonographic predictors of adnexal torsion in pediatric and adolescent patients. J Pediatr Surg 2018; 53: 1396-1398
- 20 Feng JL, Lei T, Xie HN. et al. Spectrums and outcomes of adnexal torsion at different ages. J Ultrasound Med 2017; 36: 1859-1866
- 21 Sibal M. Follicular ring sign: a simple sonographic sign for early diagnosis of ovarian torsion. J Ultrasound Med 2012; 31: 1803-1809
- 22 Lee EJ, Kwon HC, Joo HJ. et al. Diagnosis of ovarian torsion with color Doppler sonography: depiction of twisted vascular pedicle. J Ultrasound Med 1998; 17: 83-89
- 23 Ben-Ami M, Perlitz Y, Haddad S. The effectiveness of spectral and color Doppler in predicting ovarian torsion. A prospective study. Eur J Obstet Gynecol Reprod Biol 2002; 104: 64-66
- 24 Valsky DV, Esh-Broder E, Cohen SM. et al. Added value of the gray-scale whirlpool sign in the diagnosis of adnexal torsion. Ultrasound Obstet Gynecol 2010; 36: 630-634
- 25 Raban O, Zilber H, Hadar E. et al. Isolated fallopian tube torsion: a unique ultrasound identity or a serial copycat?. J J Ultrasound Med 2018; 37: 2387-2393
- 26 Warnock NG, Brown BP, Barloon TJ. et al. Spontaneous detorsion of the ovary demonstrated by ultrasonography. J Ultrasound Med 1994; 13: 57-59
- 27 Shalev J, Mashiach R, Bar-Hava I. et al. Subtorsion of the ovary: sonographic features and clinical management. J Ultrasound Med 2001; 20: 849-854