Subscribe to RSS
DOI: 10.1055/a-0991-7530
Double-balloon endoscopic ultrasound-guided gastroenterostomy: simplifying a complex technique towards widespread use
Publication History
Publication Date:
17 September 2019 (online)
Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is a novel technique for the management of gastric outlet obstruction (GOO), which has been shown to be safe and effective [1] [2]. To mitigate technical difficulties, a specialized double-balloon catheter was developed in Japan and has been found to be effective when used with an electrocautery-enhanced lumen-apposing metal stent (LAMS) [3]. Outside of Japan, however, this device is unavailable; therefore, in North America and Europe only highly specialized centers are currently performing EUS-GE using techniques that are challenging and with the potential for severe adverse events. Here we describe the performance of double-balloon EUS-GE using a widely available vascular balloon catheter ([Video 1]).
Video 1 Endoscopic ultrasound-guided gastroenterostomy for malignant gastric outlet obstruction facilitated by a double-balloon occlusion device made from a widely available vascular balloon catheter.
Quality:
A 72-year-old man with unresectable pancreatic cancer presented with recurrent GOO following previous enteral stenting and was found to have stent tumor ingrowth ([Fig. 1]). A multidisciplinary decision was made to attempt EUS-GE facilitated by double-balloon occlusion. A guidewire was endoscopically advanced through the obstructed stent deep into the jejunum. The endoscope was exchanged through an overtube to prevent looping in the stomach. Two vascular balloon catheters with a compliant balloon diameter reaching up to 46 mm when inflated (Coda balloon; Cook Medical, Bloomington, Indiana, USA) were fashioned together with the balloons set 10 cm apart ([Fig. 2]). The device was advanced distal to the obstruction over the wire using fluoroscopic guidance. The balloons were then inflated to anchor the small bowel and saline with contrast was injected through the proximal catheter, filling the bowel lumen between the balloons. On EUS, the bowel segment was visibly dilated and anchored, thereby facilitating stent insertion ([Fig. 3]). An electrocautery-enhanced 15-mm LAMS was then inserted to complete the gastroenterostomy ([Fig. 4]).
The patient tolerated a stent diet within 24 hours but required endoscopic revision 6 weeks later owing to blockage of the stent by a potassium chloride pill. No further intervention was subsequently required.
The use of EUS-GE as a first-line treatment of GOO is limited by technical challenges. The presently described double-balloon EUS-GE greatly facilitated the procedure using a device that is widely available. This may be a first step towards dissemination of this modality and will likely encourage high quality prospective trials to evaluate its role.
Endoscopy_UCTN_Code_TTT_1AS_2AG
Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.
This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos
-
References
- 1 Chen YI, Itoi T, Baron TH. et al. EUS-guided gastroenterostomy is comparable to enteral stenting with fewer re-interventions in malignant gastric outlet obstruction. Surg Endosc 2017; 31: 2946-2952
- 2 Chen YI, James TW, Agarwal A. et al. EUS-guided gastroenterostomy in management of benign gastric outlet obstruction. Endosc Int Open 2018; 6: E363-E369
- 3 Itoi T, Ishii K, Ikeuchi N. et al. Prospective evaluation of endoscopic ultrasonography-guided double-balloon-occluded gastrojejunostomy bypass (EPASS) for malignant gastric outlet obstruction. Gut 2016; 65: 193-195