Endoscopy 2019; 51(09): E239-E240
DOI: 10.1055/a-0889-7051
E-Videos
© Georg Thieme Verlag KG Stuttgart · New York

Endoscopic choledochoduodenostomy by lumen-apposing metal stent in jaundice recurrence after transpapillary metal stent placement

Andrea Anderloni
1   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
,
Alessandro Fugazza
1   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
,
Gaia Pellegatta
1   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
,
Edoardo Troncone
1   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
,
Simona Attardo
1   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
,
Annalisa Cappello
1   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
,
Alessandro Repici
1   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
2   Humanitas University, Rozzano, Milan, Italy
› Author Affiliations
Further Information

Publication History

Publication Date:
09 May 2019 (online)

Endoscopic ultrasound-guided choledochoduodenostomy (EUS-CD) with placement of an electrocautery-enhanced lumen-apposing metal stent (EC-LAMS) has been increasingly used as an alternative treatment option in patients with distal malignant biliary obstruction and failed endoscopic retrograde cholangiopancreatography (ERCP) [1] [2] [3].

We report two cases of patients who have been referred to our unit for recurrence of obstructive jaundice after previous successful transpapillary metallic stent placement for distal malignant biliary obstruction.

Case 1 was a 90-year-old woman with previous placement of a transpapillary, partially covered, biliary, self-expandable metal stent (SEMS; 40 × 10 mm) for ampullary cancer, who presented 8 months later with recurrence of obstructive jaundice.

Deep biliary cannulation by ERCP was impossible because of neoplastic duodenal infiltration, and proximal migration of the biliary SEMS was evident at fluoroscopy. EUS-guided antegrade rendezvous was unsuccessfully attempted following failure to advance the guidewire through the biliary stenosis into the duodenum.

EUS-CD was then performed by transbulbar EC-LAMS (Hot Axios, 6 × 8 mm; Boston Scientific, Marlborough, Massachusetts, USA) placement despite the presence of the biliary SEMS. 

Case 2 was an 81-year-old man with unresectable pancreatic cancer and previous placement of a biliary, uncovered SEMS (60 × 10 mm), who presented after 9 months with gastric outlet obstruction and recurrence of obstructive jaundice.

ERCP failed due to the presence of duodenal stenosis ([Fig. 1]). Therefore biliary drainage by a transbulbar EC-LAMS (6 × 8 mm) was performed despite the presence of the indwelling biliary SEMS ([Fig. 2], [Fig. 3]). Duodenal SEMS (22 × 60 mm Wallflex Enteral; Boston Scientific) was then placed during the same endoscopic session ([Fig. 4], [Video 1]).

Zoom Image
Fig. 1 Endoscopic appearance of neoplastic duodenal infiltration.
Zoom Image
Fig. 2 Endoscopic ultrasound view of biliary self-expandable metal stent in the common bile duct.
Zoom Image
Fig. 3 Endoscopic appearance of transduodenal lumen-apposing metal stent.
Zoom Image
Fig. 4 Final fluoroscopic view of biliary self-expandable metal stent, biliary lumen-apposing metal stent, and duodenal stent.

Video 1 Endoscopic ultrasound-guided choledochoduodenostomy by electrocautery-enhanced lumen-apposing metal stent and duodenal stent placement for biliary and duodenal malignant obstruction despite indwelling biliary self-expandable metal stent.


Quality:

No procedure-related adverse events were reported and a significant decrease in total bilirubin level was registered in both patients.

To our knowledge, these are the first cases of transduodenal LAMS placement for bile duct drainage conducted in patients with an indwelling biliary SEMS. Although the presence of a previously placed biliary SEMS could be considered a contraindication to the transluminal EUS-guided approach, the EC-LAMS system seemed to be helpful in overcoming possible technical difficulties, allowing a safe and effective procedure even in such complex conditions.

Endoscopy_UCTN_Code_TTT_1AS_2AG

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.
This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos

 
  • References

  • 1 Anderloni A, Buda A, Carrara S. et al. Single-session double-stent placement in concomitant malignant biliary and duodenal obstruction with a cautery-tipped lumen apposing metal stent. Endoscopy 2016; 48: E321-E322
  • 2 Jain D, Shah M, Patel U. et al. Endoscopic ultrasound guided choledocho-enterostomy by using lumen apposing metal stent in patients with failed endoscopic retrograde cholangiopancreatography: a literature review. Digestion 2018; 98: 1-10
  • 3 Mussetto A, Fugazza A, Fuccio L. et al. Through the LAMS towards the future: current uses and outcomes of lumen-apposing metal stents. Ann Gastroenterol 2018; 31: 1-6