CC BY-NC-ND 4.0 · Journal of Fetal Medicine 2022; 09(01): 1-5
DOI: 10.1007/s40556-021-00328-0
Original Article

A rapid and Easy Objective Evaluation of the Three Vessel View to Enhance Diagnostic Confidence in Fetal Echocardiography

Tomohiko Tanaka
1   Department of Pediatric Cardiology, Osaka Women’s and Children’s Hospital, Izumi, Osaka, Japan
4   Tanaka Kids Clinic, Osaka, Japan
,
2   Department of Pediatrics, Kindai University Faculty of Medicine, 377-2 Ohnohigashi, Osaka-Sayama City, Osaka, Japan
,
Yukiko Kawazu
3   Department of Pediatrics, Fukuyama City Hospital, Hiroshima, Fukuyama, Japan
,
Futoshi Kayatani
1   Department of Pediatric Cardiology, Osaka Women’s and Children’s Hospital, Izumi, Osaka, Japan
› Author Affiliations

Abstract

The three vessel view (3VV) is an integral component of fetal cardiac screening. The evaluation of vessel size is subjective in this view. Not infrequently, however, there can be a doubt and a need arises for objective assessment. Our aim was to clarify which ratio (AO/PA, AO/SVC, PA/SVC) can most easily judge the 3VV. We measured the diameter of the aorta (AO), pulmonary artery (PA) and superior vena cava (SVC) in 85 fetuses that had been diagnosed with a normal heart (NH) by the spatiotemporal image correlation (STIC) method and calculated the AO/PA ratio, AO/SVC ratio and PA/SVC ratio. We then calculated a similar index using an offline videotape in 15 fetuses diagnosed with coarctation of the aorta (COA), and 15 fetuses diagnosed with Tetralogy of Fallot (TOF). TOF excluded pulmonary atresia and absent pulmonary valve. All of the AO/PA ratios, AO/SVC ratios and PA/SVC ratios recognized a significant difference in the CoA, TOF and the NH groups. When we calculated the ROC curve in each CoA group and TOF group about AO/PA ratio, AO/SVC ratio, PA/SVC ratio, AO/PA ratio showed the highest sensitivity and specificity in the CoA group and the TOF group. When the cut-off value of the CoA for the NH group is AO/PA ratio < 0.7, good results are obtained, sensitivity is 100% and specificity is 90.6%. When the cut-off value of the TOF from the NH group is AO/PA ratio > 1.2, good results are obtained, sensitivity is 100% and specificity is 98.8%. The method to measure AO/PA ratio during heart screening can judge the 3VV objectively. When it exceeds 0.7 < AO/PA ratio < 1.2, it is likely to be congenital heart disease.



Publication History

Received: 28 July 2021

Accepted: 14 December 2021

Article published online:
04 May 2023

© 2022. Society of Fetal Medicine. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India